220V Industrial Air Conditioner |
|
|
|
This machine is suitable for hospitals, research
institutes, disaster scene ambulances, automobile repair centers,
manufacturing engineering cooling, temporary offices such as reception
rooms, equipment centralized cooling, factory production workshops,
canteens, warehouses, on-site offices, outdoor activities such as golf
practice Fields, various celebrations, temporary greenhouses, etc. |
|
Product parameter: |
|
|
|
Dimension: |
22.8"*25.9"*56"
(58cm*66cm*142.5cm) |
Voltage: |
220V |
Amp: |
8.5A
|
Btu/h: |
20400
|
Air Flow: |
3600m³/h
|
Use
environment: |
18℃~45℃
|
Power: |
1820W |
Refrigerant: |
R410A |
|
Feature: |
|
This machine is
equipped with four universal wheels, two of which are equipped with foot
brakes, making it easier to move and transport. |
Centrifugal fan
The aluminum fan
blades have strong wind force and uniform air flow. Low noise. |
|
|
The condensed water is
connected to the water, and the condensed water flowing out of the
machine can be stored here. It is necessary to observe the water volume
in the bucket in a timely manner and pour it out in a timely manner. |
This machine is
equipped with a controller, which can start the machine with one click,
with adjustable air volume, cold air temperature, and environmental
temperature. |
|
|
This machine is
equipped with a high-efficiency evaporator with a detachable filter
screen for easy cleaning. |
BIG
WATER TANK(14L)
This
machine is equipped with a water tank that can receive condensate water,
making it easy to see the amount of water and discharge it in a timely
manner. |
|
|
|
1.
Simple Operation.
2. High-efficiency performance
3. Simple operation, long service life, high efficiency, power save
4. Simple and easy installation.Simple and easy installation.
5.Filters dust and dehumidifies.
6.Great for times when temporary cooling is needed.
7.Caster wheels allow for easy transport and relocation.
8. With pulleys, light and flexible.
9. Large air volume, strong refrigeration, low energy consumption, low
noise, long life and stable operation.
10. Using R410A refrigerant, the temperature is comfortable.
11. The compressor can be used for refrigeration in a high temperature
environment of 45℃.
12. Using a fully automatic control system, with automatic diagnosis
function, effectively prevent damage to the machine due to bad
operations.
|
Precautions: |
1. This product is
industrial cooling and air-conditioning equipment, not a houseware.
2. This product is a
local cooling air-conditioning equipment. The cooling and heat
dissipation are on the same machine, which is different from the
traditional household split air conditioner.
This machine cannot cool the whole space (if the whole space needs to be
cooled down, it is necessary to install pvc hose or aluminum foil single
tube at the hot air outlet to discharge the hot air outside,this model
needs to choose a 40cm size hose)
3. The design and use
environment of this product is 18-45℃. If the temperature is lower than
or higher than this temperature zone, the equipment will not operate
normally, not the product itself is malfunctioning.
4. The noise of this
product is 60-70 decibels, which is not suitable for occasions that
require noise (such as bedrooms, meeting rooms, offices, libraries,
etc.).
|
|
Method of operation: |
●Power switch
Turn on the power, the power switch indicator light is on, press the
button to turn on and off the machine.
●Air volume selection
Press the button to choose automatic wind
●Cold air temperature setting
Press the cold air temperature setting key, and the cold air temperature
indicator will light up at the same time. At this time, press the upper
and lower temperature adjustment buttons to set the desired outlet air
temperature, that is, run in the cold air set temperature mode. The cold
air temperature can be set from 0°C to 30°C. When the cold air
temperature is 1°C higher than the set temperature, the compressor works
and the air outlet outputs cold air; when the cold air temperature is
1°C lower than the set temperature, the compressor stops working and the
air outlet outputs natural air.
●Environmental temperature setting
Press the button, the machine detects and displays the inlet air
temperature, and the inlet air temperature indicator lights up at the
same time. Press the upper and lower temperature adjustment buttons to
set the desired inlet air temperature, that is, run in the inlet air set
temperature mode, and the inlet air temperature can be set from 18°C
to 35°C. When the inlet air temperature is 1°C higher than the set
temperature, the compressor works, and the air outlet outputs cold air;
when the inlet air temperature is 1°C lower than the set temperature,
the compressor stops working, and the air outlet outputs natural air.
●Alarm indicator
When the machine is full of water, overcurrent, overheating, or
ultra-high pressure, the alarm indicator will light up, the machine will
stop running, and the LED display will show the corresponding fault
code. |
Details: |
|
|
Maintenance and inspection: |
Please clean
the filter regularly. If dust and dirt accumulate on the filter, it will
affect the air intake, easily cause frost on the heat exchanger, affect
the cooling effect, and cause the machine to malfunction.
●To clean the
filter, please lift the filter up and then take it out directly.
Use a vacuum
cleaner to absorb the dust on the filter, then clean it with water or a
neutral detergent, and restore it to use after it is completely dry.
Note!!!!
When cleaning the surface of the machine, do not use chemicals such as
thinner, volatile oil, etc., otherwise it will affect the appearance of
the machine.
●Please
always check whether the parts and screws are loose. If there is any
looseness, please tighten it in time to remove it. Before the machine is
not used for a long time, please pour out the accumulated water in the
water storage bucket and store it after the machine is dry.
●Do not store
the machine horizontally or upside down.
●Please keep
the machine out of the reach of children, and avoid storing it in places
subject to high temperature, splashing rain and direct sunlight.
●During
maintenance and inspection, be sure to cut off the power supply.
●Be sure to cut
off the power supply when storing the machine.
|
Product display: |
|
|
|
|
Item Included:1*220V
Industrial air conditioner |
Item Number: 023472 |
|
You can make order
with no worry.
Any concerns just feel free to let us know, we'll reply in 24 hours in
normal condition.
Handling Time: Shipping is usually made in 1-3 business days after
payments cleared. Orders are processed from Monday-Friday; Not on the
weekends & public holidays.
Warranty: 6 months' warranty for the machines, not for the consumables.
We stand behind our products all the item, so even if your warranty
period has expired, you can still seek for service or technical support
from us with low cost. |
|