142012:Withstand Hi-Pot Tester - RK2672AM
Unit:
set
Price:
455.00$
Weight:
10.70kg
QTY:
           
     

Similar products

025030:INTBUYING Melt Flow Index Rate Tester MFR Tester Indexer Flow Rate Meter for Plastic Lab Supply

239624:Paint Film Cone Bending Tester

239640:Textile Fabric Waterproof Testing Machine

239794:Battery Capacity Tester Lead Acid Lithium Iron 5A Charge 20A Discharge

154003:Portable Skid Resistance Tester

Withstand Hi-Pot 5KV 100VA Tester

RK267 series voltage withstand test instruments are for general- purpose HV test operation, It can be widely used for voltage withstand test in electrician’s assistant instrument,rubber-wooden facility,voltage convertor,wires , power meter, motor, power supply plug, cables and all kinds of electronic and electric products. As the launch of the national security standard, Voltage  withstand  instrument  has  become  one  of  necessary  withstand  test instruments to the radio and electronic products manufacturer.
   Operating request: Environmental temperature 0~40

                             Relative dumidity≤75%

http://topseller365.com/data/prd/142/012/1.jpg

Paraments

Model RK2672AM
Description Klgital display with remote control
Test Voltage (AC) 0~5KV +/-5%
Test Voltage (DC) 0~5KV +/-5%
Leakage Current (AC) 0~2/20mA +/-5%
Leakage Current (DC) 0~2/10mA +/-5%
Timing (s) 0~99s; Manual control
Pmax 100VA
Input Voltage 110V
Weight 24LB
 
        http://topseller365.com/data/prd/142/012/chicun.jpg
Details

http://topseller365.com/data/prd/142/012/2.jpg

http://topseller365.com/data/prd/142/012/6.jpg

http://topseller365.com/data/prd/142/012/11.jpg

Pre-used Caution

  Read  the  following  items  carefully  before  operating  RK267 series voltage withstand test instrument
   1. Use three-hole power supply plug and insure GND connection well.

  2. GND port and power supply GND port should be connected well.

  3. Wear insulation glove, stand on   insulation mat.

  4. Anti-clockwisely  circumvolve  V-ADJ  rotary  switch  to  the maximum before turn on test instrument.

  5. Before preset all functions, reset instrument.

  6 6. Dont connect test port and test wire when doing test.

  7. Dont connect HV output port with shield box or GND wire to avoid instrument damage.

  8. Turn off power when accident take place.

  9. Examine and repair when Indicator or annunciator is out of function .
  10. Operate carefully to avoid hazard when take the remote test.
  11.The instrument must be placed on the worktable of conductive materials
  12.The operator can not wear clothes with metal decoration or wear metal accessories
  13.When the tester is in the test conditions, the test line, the test probes, output end , and the
test objects are all with high pressure, do not touch!

Item Included:(142012)2)
Withstand Hi-Pot Tester - RK2672AM
1×Withstand voltage test equipment

1×High voltage test bar
1×Remote control test bar
1×Ground wire
1×power cord
  

 

 
Item Number:

You can make order with no worry.
Any concern just feel free to let us know, we'll reply in 24 hours in normal condition.
Handling Time: Shipping is usually made in 1-3 business days after payments cleared. Orders are processed from Monday-Friday; Not on the weekends & public holidays.
Warranty: 6 months' warranty for the machines, not for the consumables.
We stand behind our products all the item, so even if your warranty period has expired, you can still seek for service or technical support from us with low cost.

无标题文档

About Us Product Service Shipping Payment Privacy refund Warranty

Copyright INTBUYING.com All Rights Reserved