MAC-150 220V
Industrial Air Conditioner |
|
|
|
This machine is suitable for hospitals, research
institutes, disaster scene ambulances, automobile repair centers,
manufacturing engineering cooling, temporary offices such as reception
rooms, equipment centralized cooling, factory production workshops,
canteens, warehouses, on-site offices, outdoor activities such as golf
practice Fields, various celebrations, temporary greenhouses, etc. |
 |
Product parameter: |
 |
Dimension: |
56.1"*32.9"*41.33"
(142.5cm*83.5cm*105cm) |
Voltage: |
220V
Three-phase electricity |
Maximum current: |
13.2A |
Rated current: |
10.5A |
Btu/h: |
51100
|
Air Flow: |
2700m³/h
|
Hot air discharge: |
7000m³/h |
Use environment: |
18℃~45℃ |
Power: |
6000W |
Condensation water treatment
method: |
Connect the water pipe from the outside |
Refrigerant: |
R410A |
|
Feature: |
 |
This machine is equipped with 2
universal wheels with foot brakes, which is very convenient for movement
and handling. |
This machine is equipped with 2
directional wheels without foot brakes, which is more convenient to
move. |
 |
 |
This machine adopts the method of
discharging condensed water from an external water pipe, with a pipe
diameter of 2.7cm. |
Thicken the filter screen and upgrade
the thickened material to effectively prevent dust from entering. |
 |
 |
This machine is intuitive, simple, and
easy to operate. |
1. High-efficiency performance
2. Simple operation, long service life, high efficiency, power save
3. Simple and easy installation.
4.Filters dust and dehumidifies.
5.Great for times when temporary cooling is needed.
6.Caster wheels allow for easy transport and relocation.
7.Large in size but easy to move.
8.Easy Self-Diagnosis function. |
Precautions: |
1. This product is industrial cooling and
air-conditioning equipment, not a kind of houseware.
2. This product is a
kind of local cooling air-conditioning equipment. The cooling and heat
dissipation are on the same machine, which is different from the
traditional household split air conditioner.
This machine cannot cool the whole space (if the whole space needs to be
cooled down, it is necessary to install a pvc hose or aluminum foil
single tube at the hot air outlet to discharge the hot air outside,this
model needs to choose hose with the 56cm size,The cold air outlet needs
to be connected to an air outlet duct with the 25cm diameter.)
3. The design and use
environment of this product is 18-45℃. If the temperature is lower than
or higher than this temperature zone, the equipment will not operate
normally rather than malfunction.
4. The noise of this
product is 60-70 decibels, which is not suitable for occasions that
require low noise (such as bedrooms, meeting rooms, offices and
libraries.).
Note:This machine is not equipped with a power cord, you need to wire
their own, if you do not know how to wire, you can contact our customer
service and we will provide you with the wiring video.
|
Operation method: |
1.Take power directly
from the socket that meets the specified voltage and frequency of the
equipment. If an extension cord is needed, select a 4.0mm² model
for cords within 8 meters.
2.Press the green
start button (at this time, the indicator light of the green start
button is on, and the centrifugal fan starts to work). If refrigeration
is required, press the refrigeration button (the indicator light of the
green refrigeration button is on, the temperature control indicator is
always on, and the refrigeration system starts to operate).
3. Use of controllers:
(1)working normally,
press and hold the Set Key for more than 3 seconds to enter the
parameter modification mode. The Setting Indicator Light will turn on,
and the digital screen will display the first menu item code "F1".
(2)Press the "▲" or
"▼" key to scroll up or down through the menu items and display the
corresponding codes. Press the Set Key to show the parameter setting
value of the current menu item, then press the "▲" or "▼" key again to
adjust the parameter.
(3)After the settings
are completed, press the Set Key to return to the parameter code, and
press the corresponding key to save the modifications and return to the
normal temperature display state.
(4)If there is no
operation within 10 seconds, the modifications will not be saved and the
controller will return to the normal display. If an error occurs during
parameter saving, "Er" will be displayed, and it will return to the
normal state after 3 seconds.
4.Turn off:When the
machine is not in use,press the stop button, and the device will stop
running.
(note:When the machine is working
normally, after turning off the power switch, you need to wait 3 minutes
before starting it again.)
|
Details: |
 |
 |
 |
 |
Product display: |
 |
 |
Item Included:1*MAC-150
220V Industrial Air Conditioner |
Item Number: 023531 |
|
You can make
order with no worry.
Any concerns just feel free to let us know, we'll reply in 24 hours in
normal condition.
Handling Time: Shipping is usually made in 1-3 business days after
payments cleared. Orders are processed from Monday-Friday; Not on the
weekends & public holidays.
Warranty: 6 months' warranty for the machines, not for the consumables.
We stand behind our products all the item, so even if your warranty
period has expired, you can still seek for service or technical support
from us with low cost. |
|